Data Sheet
Bridge Module



The Bridge Module commissions the system, recovers any module in a plug-and-play manner in the event of a component failure, and communicates with the outside world. But because it doesn't actually control the individual modules, we have removed the possibility of a single-point system failure.

The Bridge Module monitors and securely connects the automation system to support personnel, and sends alerts in the event of a module fault. It is programmable for future event scheduling - for instance, to change the kid's bedroom lighting from story-time to bedtime each night at the appointed hour. It also works in tandem with our unique system design software to make future design upgrades a cinch.

   
Permits scheduling of events based on the time of day
System diagnostics & monitoring calls for service as soon as it’s needed
Module recovery restores normal operations when modules are replaced
As-Built data storage makes future remodeling easier
   
Technical Specifications
General Standards/Approvals UL/cUL (safety): 60950
FCC Part 15 (emissions): Class B
CAN 2.0B Compliant
Patents Pending
  Data Storage non-volatile Compact Flash Card
  Clock Accuracy -2.2, +3.8 sec/day
Electrical Input 12VDC, 2.0A max, 1.0A typ.
  Real-time Clock battery 3V Lithium CR1632
Physical Interfaces/Communication RJ45 - 10/100 Mbps Ethernet
USB Type A Recpts - Colorado vNet Peripherals Port
Male DB9 - DTE RS232
RJ-45 CAN Bus
  Buttons Reset - Board Reset
Paperclip - Commissioning and Address Reset
  Indicators Reset - Reset active
Power - Power to unit
Xmt - Ethernet transmit active
Rcv - Ethernet receive active
Status - Multi-mode status indicator
  H x W x D 8.2" x 5.2" x 1.2"
  Weight 1.3 lbs
Environment Operating Temperature 0 deg. C to 40 deg. C (32 deg. F to 104 deg. F)
Accessories Included AC Power Adapter
512MB Compact Flash Card (max 4GB)
Real-time Clock Battery
 